<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
<title>Fen Bilimleri Enstitüsü</title>
<link href="https://acikerisim.bingol.edu.tr/handle/20.500.12898/1357" rel="alternate"/>
<subtitle>Institute of Sciences</subtitle>
<id>https://acikerisim.bingol.edu.tr/handle/20.500.12898/1357</id>
<updated>2026-11-23T16:34:14Z</updated>
<dc:date>2026-11-23T16:34:14Z</dc:date>
<entry>
<title>Atık Araç Lastiklerinin Polimerlerle Kompozitlenerek Çevre Dostu Yapı Malzemesi Üretimi</title>
<link href="https://acikerisim.bingol.edu.tr/handle/20.500.12898/6505" rel="alternate"/>
<author>
<name>Canan, KAYA ŞAHİN</name>
</author>
<id>https://acikerisim.bingol.edu.tr/handle/20.500.12898/6505</id>
<updated>2026-11-23T12:20:26Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Atık Araç Lastiklerinin Polimerlerle Kompozitlenerek Çevre Dostu Yapı Malzemesi Üretimi
Canan, KAYA ŞAHİN
ÖZET: Atık araç lastiklerinin yapı malzemelerine dönüştürülmesi, kaynakların yeniden değerlendirilmesi açısından önem taşımaktadır. Bu çalışmada epoksi, poliüretan, novolak–hekzamin ve doymamış polyester bağlayıcılar, dört granül düzeninde karşılaştırılmıştır. Dayanım ve deformasyon davranışının bağlayıcı türü ile granül düzeninin birlikte etkisine bağlı olduğu araştırılmıştır. Oluşturulan 16 formülasyon için 3, 28 ve 90 günlük basınç deneylerinin her birine 48 adet olmak üzere toplam 144 basınç numunesi hazırlanmıştır. Ayrıca 48 eğilme ve 16 ısıl iletkenlik numunesi üretilmiş; ana deney programındaki toplam numune sayısı 208 olmuştur. Basınç sonuçlarında deney yaşları arasında Friedman testiyle anlamlı fark saptanmamış (p = 0,983); 28 gün ortak mekanik karşılaştırma yaşı olarak kullanılmıştır. Ana bağlayıcı oranı granül kütlesine göre %20 tutulmuştur. Ultrasonik geçiş hızı, 13 gerilme–birim şekil değiştirme kaydı, SEM/EDS, ATR-FTIR ve temsilci TGA/DTG analizleri birlikte değerlendirilmiştir. Isıl iletkenlik karşılaştırması, üretilen 16 plaka içinden dört bağlayıcının K4 düzenine ait raporlanan dört ölçümle sınırlandırılmıştır. Epoksi–K1, 8,21 MPa basınç ve 2,21 MPa eğilme dayanımıyla öne çıkmıştır. Poliüretan–K4, 6,29 MPa basınç ve 1,94 MPa eğilme dayanımıyla geniş görünür deformasyon aralığı göstermiştir. Novolak–hekzamin–K2 dayanım, K3 ise tepe sekant rijitliği bakımından belirginleşmiştir. Polyester mevcut reçetede daha düşük mekanik değerler vermiştir. K4 kompozitlerinin 20 °C’deki ısıl iletkenliği 0,1486–0,1998 W/(m·K) aralığında bulunmuş; en düşük değer poliüretanda ölçülmüştür. Sonuçlar, özellikle poliüretan esaslı esnek derz ve sismik ara elemanların araştırılmasını desteklemiş; doğrudan izolatör uygunluğu ve yangın güvenliği doğrulanmamıştır.; ABSTRACT: Recovering waste tires for construction materials can support resource reuse. This study compared epoxy, polyurethane, novolac–hexamine and unsaturated polyester binders across four granule arrangements. The combined influence of binder type and granule arrangement on strength and deformation was investigated. The 16 formulations required 48 compression specimens at each of 3, 28 and 90 days, totaling 144 compression specimens. Additionally, 48 flexural specimens and 16 thermal-conductivity specimens were produced, giving 208 specimens in the main experimental program. The Friedman test detected no significant age effect on compressive strength (p = 0.983); 28 days was adopted as the common mechanical comparison age. The main binder content was 20% of granule mass. Ultrasonic pulse velocity, 13 stress–strain records, SEM/EDS, ATR-FTIR and representative TGA/DTG analyses were evaluated together. Thermal comparison was restricted to the four reported K4 measurements among the 16 plates produced. Epoxy–K1 achieved 8.21 MPa compressive and 2.21 MPa flexural strength. Polyurethane–K4 reached 6.29 and 1.94 MPa, respectively, with a broad apparent deformation range. Novolac–hexamine–K2 showed favorable strength, whereas K3 exhibited higher peak secant stiffness. Polyester showed lower mechanical performance under the investigated formulation. Thermal conductivity of the K4 composites ranged from 0.1486 to 0.1998 W/(m·K) at 20 °C, with the lowest value measured for polyurethane. The findings support further investigation of flexible joints and seismic interface elements, particularly polyurethane-based systems; direct isolator suitability and fire safety were not established.
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Barış Manço Kültür ve Kongre Merkezi Enerji Tüketimi Analizi</title>
<link href="https://acikerisim.bingol.edu.tr/handle/20.500.12898/6503" rel="alternate"/>
<author>
<name>TURAN, Orhan</name>
</author>
<id>https://acikerisim.bingol.edu.tr/handle/20.500.12898/6503</id>
<updated>2026-11-23T08:43:56Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Barış Manço Kültür ve Kongre Merkezi Enerji Tüketimi Analizi
TURAN, Orhan
ÖZET:&#13;
İnsanların kendilerini güvende hissederek vakit geçirdikleri kongre ve kültür merkezleri ruhsal ihtiyaçları da karşılayacak şekilde tasarlanmaktadır. Kültür merkezleri sinema salonları, eğlence mekânları, yeme içme alanları, mağazalar gibi birçok birimden oluşmaktadır. Sosyal ihtiyaçlarını karşılamak için ayırdıkları vakitlerini kültür merkezlerinde geçiren birçok insanın uzun süre kaldıkları bu mekânlarda kendilerini konforlu hissetmeleri gerekliliği kaçınılmazdır. Bu nedenle kültür merkezleri tasarımında işitsel, görsel ve ısıl konfor gibi konfor koşullarının sağlanması gerekir. Konfor koşullarına uygun tasarım yapılması insanların rahatsızlık duymadığı bu mekânları tercih etmesinde en büyük etkendir. Konfor koşullarının sağlanması sırasında enerjinin etkin kullanımına da önem verilmelidir. Enerji kaynaklarının tüketiminin artması, CO2 salınımının artması, çevre kirliliği, küresel ısınma, ekosistemin bozulması gibi sorunlara çözüm olabilecek yapıların yapılması elzemdir. Bu çalışmada, Barış Manço Kültür ve Kongre Merkezi'nin enerji tüketimi analiz edilmiştir. Çalışma kapsamında, kültür merkezinin yıllık enerji tüketim verileri incelenmiş, binaların mimari yapısı, ısıtma ve soğutma sistemleri, aydınlatma sistemleri ve enerji verimliliği analiz edilmiştir. Bulgular, binanın mevcut enerji tüketim seviyesinin yüksek olduğunu ve çeşitli enerji tasarrufu önlemleriyle önemli ölçüde azaltılabileceği tespit edilmiştir. Öneriler arasında bina yalıtımının iyileştirilmesi, verimli aydınlatma sistemlerinin kullanılması, ısıtma ve soğutma sistemlerinin optimize edilmesi ve enerji verimliliğinin artırılması kapsamında, bina kabuğunun iyileştirilmesi, yüksek verimli mekanik sistemlerin kullanılması yenilenebilir enerji sistemleri ile entegrasyonu önerilmektedir. Bu önlemler enerji maliyetlerini azaltmanın yanı sıra, çevresel sürdürülebilirliği artıracak ve binanın konfor koşullarını iyileştirecektir. Çalışmanın sonuçları, enerji verimliliği projelerinin uygulanması durumunda, kültür merkezinin enerji tüketiminde kayda değer bir azalma sağlanabileceğini ve bu projelerin maliyet etkinliğini göstermektedir.; ABSTRACT:&#13;
In this study, the energy consumption of the Barış Manço Culture and Congress Center was analyzed. Cultural centers are multifunctional spaces where individuals spend extended periods of time, fulfilling both their social and, in some cases, spiritual needs. These facilities typically include various units such as auditoriums, cinemas, dining areas, and retail spaces. Therefore, ensuring user comfort in such environments is of great importance.&#13;
In the design of cultural centers, factors such as thermal comfort, visual comfort, and acoustic comfort must be carefully considered. Providing optimal comfort conditions is a key determinant in user satisfaction and space preference. At the same time, it is essential to ensure energy efficiency while maintaining these comfort conditions.&#13;
This study evaluates the annual energy consumption data of the Barış Manço Culture and Congress Center, taking into account the building’s architectural characteristics, heating and cooling systems, and lighting systems. The findings reveal that the current level of energy consumption is relatively high and can be significantly reduced through appropriate energy-saving measures.&#13;
Recommended strategies include improving thermal insulation, adopting energy-efficient lighting systems, optimizing heating and cooling operations, and integrating renewable energy sources. These measures are expected not only to reduce energy consumption and operational costs but also to enhance environmental sustainability and indoor comfort conditions.&#13;
The results demonstrate that implementing energy efficiency strategies can lead to substantial reductions in energy consumption in cultural buildings, while also improving overall performance and cost-effectiveness.
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Betonarme Bir Okul Yapısının Güçlendirme Öncesi ve Sonrası Yapısal Davranışının Karşılaştırmalı Analizi</title>
<link href="https://acikerisim.bingol.edu.tr/handle/20.500.12898/6502" rel="alternate"/>
<author>
<name>AYDIN, İbrahim</name>
</author>
<id>https://acikerisim.bingol.edu.tr/handle/20.500.12898/6502</id>
<updated>2026-11-23T08:27:06Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Betonarme Bir Okul Yapısının Güçlendirme Öncesi ve Sonrası Yapısal Davranışının Karşılaştırmalı Analizi
AYDIN, İbrahim
ÖZET:&#13;
Türkiye’de eğitim yapılarının deprem güvenliği, bilhassa 6 Şubat 2023 Kahramanmaraş depremleri sonrasında, mevcut okul yapılarının performanslarının değerlendirilmesini zorunlu kılmıştır. Çalışmada, betonarme bir okul yapısının güçlendirme öncesi ve sonrası yapısal davranışı; taban kesme kuvvetleri, kat ötelemeleri, kütle ve rijitlik merkezleri, momentleri ve periyotları karşılaştırmalı olarak incelenmiştir. Yapı, ortamında üç boyutlu modellenmiş; malzeme ve uygunluk kriterleri TBDY 2018’e göre tanımlanmış ve mevcut durum için analizler gerçekleştirilmiştir. Zaman tanım alanı aşamasında, AFAD veri tabanından seçilen üç ivme kaydı (3123, 3125, 3133) hem ölçeklendirilmemiş (THA) hem de hedef spektruma uyumlu ölçeklendirilmiş (THA-M) olarak kullanılmıştır. Güçlendirme yöntemi olarak betonarme perde ilavesi eklenmiş ve aynı analizler tekrarlanmıştır. Sonuçlar, deprem kayıtları arasında 3125’in en yüksek (en yüksek pga değerine sahip kayıt), 3133’ün en düşük (en düşük pga değerine sahip kayıt) talebi göstermiştir. Kütle ve rijitlik merkezlerinin birbirine yaklaşması burulma sonuçlarını azaltmış ve iç kuvvet dağılımını daha uyumlu hale getirmiştir. THA-M analizleri, THA’ya kıyasla daha düşük sonuçlar vererek kayıtlar arası yayılımı düşürmüştür. Ayrıca genel olarak, X doğrultusunda taleplerin çoğu durumda Y’ye göre daha büyük olduğu; bunun rijitlik dağılımı ve mod kütle eşliğiyle ilişkili olduğu görülmüş, çalışma bu bulgularla TBDY 2018 kapsamında okul güçlendirme kararlarına pratik bir dayanak sunmuştur.; ABSTRACT:&#13;
In Turkiye, the seismic safety of educational buildings, especially after the February 6, 2023 Kahramanmaraş earthquakes, has made it necessary to evaluate the performance of existing school buildings. In this study, the structural behavior of a reinforced concrete school building before and after strengthening was comparatively examined, including base shear forces, story displacements, centers of mass and rigidity, moments, and periods. The structure was modeled in three dimensions in the finite element based software environment; material and suitability criteria were defined according to TBDY 2018, and analyses were performed for the existing condition. In the time-domain phase, three acceleration records (3123. 3125. 3133) selected from the AFAD database were used both unscaled (THA) and scaled (THA-M) compatible with the target spectrum. Reinforced concrete shear wall addition was added as a strengthening method, and the same analyses were repeated. The results showed that among the earthquake records, 3125 had the highest demand (biggest pga value), and 3133 (lowest pga value) had the lowest. While story displacements decreased significantly with the increase in stiffness after strengthening, an increased tendency for base shear forces was observed for various records. The convergence of the centers of mass and stiffness reduced torsional results and made the internal force distribution more harmonious. THA-M analyses yielded lower results compared to THA, reducing the spread between records. In addition, it was observed that the demands in the X direction were generally greater than those in the Y direction in most cases; this was related to the stiffness distribution and mode-mass equality, and with these findings, the study provides a practical basis for school strengthening decisions within the scope of TBDY 2018.
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Sütte Bulunan Eksozomların Nano-LC Sisteminde Analizi</title>
<link href="https://acikerisim.bingol.edu.tr/handle/20.500.12898/6500" rel="alternate"/>
<author>
<name>GÜNYEL, Zeynep</name>
</author>
<id>https://acikerisim.bingol.edu.tr/handle/20.500.12898/6500</id>
<updated>2026-11-12T11:46:33Z</updated>
<published>2023-01-01T00:00:00Z</published>
<summary type="text">Sütte Bulunan Eksozomların Nano-LC Sisteminde Analizi
GÜNYEL, Zeynep
ÖZET:&#13;
Bu tez çalışmasının amacı, ters faz nano-sıvı kromatografisi (nano-LC) için yeni metakriloil grafen oksit nano partikül (MGONP) bazlı hidrofobisitesi artırılmış monolitik nano kolonların hazırlanması ve bu kolonların süt numunelerinden eksozomların ayrımı ve analizi için nano-LC sisteminde kullanılması olarak belirlenmiştir. Bu bağlamda, çalışma kapsamında MGONP’leri grafit kullanılarak elde edilmiş ve MGONP içeriğine sahip monolitler hazırlanarak karakterizasyon çalışmaları yapılmıştır. İlk olarak, monolitik kolonlar, butilmetakrilat (BMA), etilen dimetakrilat (EDMA) ve MGONP içeren solüsyonlar hazırlanmış, porojenik çözücü olarak dimetilformamid (DMF) ve su kullanılmıştır. Hazırlanan polimerik solüsyon 50 μm i.d.’lik fused silika kapiler kolonlar içerisine enjekte edilerek in-situ polimerizasyon yöntemi ile monolitik kolonlar hazırlanmıştır. Hazırlanan kolonların hidrofobisitesinin artırılması için, kolonlar dimetiloktadesilklorosilan (DODCS) ile modifiye edilmiştir. Karakterizasyon için monolitik kolonların morfolojik yapıları SEM görüntüleri ve FT-IR analizleri ile incelenmiştir. Ayrıca, hazırlanan monolitik nano kolonların kromatografik karakterizasyonu nano-LC’de alkilbenzen homologları kullanılarak yapılmıştır. Karakterizasyonu yapılmış monolitik kolonlar kullanılarak nano-LC sisteminde sütten ekstrakte edilen eksozom ayırımı ve analizi için kromatografik optimizasyon çalışmaları yapılmıştır. Eksozomlar karakterizasyon ve tanımlamaları için NTA, SEM, FT-IR kullanılmış ve sonrasında etkin olarak nano-LC’de kromotografik analizleri yapılmıştır. Geliştirlen yöntemin etkin sonuç verdiği ve yeni bir yaklaşımla eksozom izolasyon yöntemi geliştirilmiş olduğu görülmüştür.; ABSTRACT:&#13;
The aim of this thesis is to prepare methacryloyl graphene oxide nanoparticles (MGONPs) based monolithic nano-columns with increasin hydrophobicity for the separation and analysis of exosomes in milk samples. In this thesis, graphite was used for the synthesis of MGONPs and the preparation adn characterization of the developed monolithic columns were performed. Firstly, the monolithic columns are prepared using polymeric solutions composing of BMA EDMA and MGONPs and DMF/H2O as porogenic solvent. The final solution for monolithic column preparation was injected into the fudes silica capillary column with 50 μm i.d. in order to make in-situ polymerization. Final monolithic columns are modified for the increasing their hydrophobicity, which is neccessary for exosome separation and analysis. SEM images and FT-IR are applied for the characterization of monolithic columns as well as chromatographic characterization with homologous alkylbenzenes. The characterized monolithic olumns are applied for the separation and analaysis of exosomes in milk samples by using reversed-pahse nano-LC. In addtion to nano-LC studies, NTA, SEM and FT-IR are used for the tandem characterization of exosomes. All results shows that the developed tecnique is a novel and promising methadology for exosome isolation and it is proposed as a novel approach for exosome isolation.
</summary>
<dc:date>2023-01-01T00:00:00Z</dc:date>
</entry>
</feed>
