• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • 2.Enstitüler / Institutes
  • Fen Bilimleri Enstitüsü
  • Gıda Güvenliği
  • View Item
  •   DSpace Home
  • 2.Enstitüler / Institutes
  • Fen Bilimleri Enstitüsü
  • Gıda Güvenliği
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Bazı Bal Numunelerindeki Bisfenol A (Bpa)’Nın Nano-LC Sisteminde Belirlenmesi

Thumbnail
View/Open
Şahriban KARDAŞ-Y.L. Tezi.pdf (1.543Mb)
Date
2024
Author
KARDAŞ, Şahriban
Metadata
Show full item record
Abstract
ÖZET: Bisfenol A, insan sağlığına olumsuz etkileri nedeniyle üzerinde en çok çalışılan bileşik olup, dünya çapında gıda ile temas eden malzemelerde en yaygın kullanılan ürünlerden biridir. Bu çalışma kapsamında ters faz nano-LC sistemi ile balda bisfenol A (BPA) tayini için naftalen metil metakrilat (NMM) bazlı yeni bir hidrofobikçzellikte monolitik nano-kolon hazırlanmış ve karakterize edilmiştir. Hazırlanan monolitik kolon kullanılarak, nano-LC yöntemi ile BPA’nın, gözlenebilme sınırı (LOD) ve alt tayin sınırı (LOQ) sırasıyla 0,02μg/L ve 0,58 μg/L saptanmıştır. Yüzde bağıl standart sapma (%RSD) değeri ise, gün içi ve günler arası tekrarlanabilirlik değerlerinde sırasıyla 2,1 ve 1,8 belirlenmiştir. Geliştirilen yöntem ile on üç ticari bal örneğininde BPA analizi yapılmıştır. Beş bal örneğinde 2,5±0,27 μg/L-12,47±0,84 μg/L arasında değişen miktarlarda BPA tespit edilmiştir.
 
ABSTRACT: Bisphenol A is the most studied compound due to its adverse effects on human health and is one of the most widely used products in food contact materials worldwide. Within the scope of this study, a new hydrophobic monolithic nanocolumn based on naphthalene methyl methacrylate (NMM) was prepared and characterized for the determination of bisphenol A (BPA) in honey by reverse phase nano-LC system. The limit of detection (LOD) and limit of quantification (LOQ) of BPA were determined to be 0.02μg/L and 0.58μg/L, respectively, by reverse phase nano-LC method using a prepared monolithic column. The percent relative standard deviation (%RSD) value was determined as 2.1 and 1.8, respectively, for intraday and interday repeatability values. The developed method was applied to the analysis of thirteen commercial honey samples. BPA was detected in five honey samples in amounts ranging from 2.5±0.27 μg/L to 12.47±0.84 μg/L.
 
URI
http://acikerisim.bingol.edu.tr/handle/20.500.12898/5645
Collections
  • Gıda Güvenliği [7]





Creative Commons License
DSpace@BİNGÖL by Bingöl University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 



| Politika | Rehber | İletişim |

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV