• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • 6.Araştırma Çıktıları / Research Outcomes(WOS-Scopus-TR-Dizin-PubMed)
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • 6.Araştırma Çıktıları / Research Outcomes(WOS-Scopus-TR-Dizin-PubMed)
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Turbidity measurements and modified imhoff cone method for estimation of suspended sediment concentration

Thumbnail
Tarih
2010
Yazar
Meral, R. and Dogan, E. and Demir, Y.
Üst veri
Tüm öğe kaydını göster
Özet
The requirement for monitoring of suspended sediment concentrations (SSCs) with good temporal and spatial resolution has led to the development of methods for sediment measurements. In this study, two practical and relatively cheap alternative methods (namely turbidity sensor and Imhoff cone method) were used to estimate SSC. Imhoff cone is a practical and indirect free settleable solid analysis method. Although this method is easy to use and cheap, moving the water samples to the laboratory and allowing them to settle can be time consuming. Therefore Polyacrylamide (PAM), which is a soil conditioner and a flocculant, was tested as an accelerant of sediment settling in Imhoff cone method. PAM concentrations of 0.05 and 0.1 ppm were used in water samples. The results showed that it causes turbidity sensor measurement method had high reliability and advantage including continuous monitoring and ability to read and store more data at high expected sediment concentrations (<10.0 g/L). Finalizing the flocculation and settling material stabilization processes in a short time, like 10 min, increased the use of Imhoff cone method in the field conditions without having to move samples to the laboratory. However, this method had disadvantages of causing errors at low sediment concentrations and requiring sensitive measurements due to the graduation of the cone. These problems can be solved by using better graduated cones or digital sensors in the cones. Finally, this study showed that these methods have potential with high reliability and are good alternatives for practical and economical sediment measurements. © by PSP.
Bağlantı
https://www.scopus.com/inward/record.uri?eid=2-s2.0-79952589458&partnerID=40&md5=d9fa7f328070245782f47db8db715ec9
http://acikerisim.bingol.edu.tr/handle/20.500.12898/5066
Koleksiyonlar
  • Scopus İndeksli Yayınlar Koleksiyonu [1357]





Creative Commons License
DSpace@BİNGÖL by Bingöl University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 



| Politika | Rehber | İletişim |

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreBy TypeBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreBy Type

Hesabım

GirişKayıt

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV