• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • 6.Araştırma Çıktıları / Research Outcomes(WOS-Scopus-TR-Dizin-PubMed)
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • 6.Araştırma Çıktıları / Research Outcomes(WOS-Scopus-TR-Dizin-PubMed)
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Novel tentacle-type polymer stationary phase grafted with anion exchange polymer chains for open tubular CEC of nucleosides and proteins

Thumbnail
Date
2014
Author
Aydoğan, C. and Çetin, K. and Denizli, A.
Metadata
Show full item record
Abstract
A novel and simple method for preparation of a tentacle-type polymer stationary phase grafted with polyethyleneimine (PEI) anion exchanger was developed for open tubular capillary electrochromatography (OT-CEC) of nucleosides and proteins. The polymeric stationary phase was prepared using 3-chloro-2-hydroxypropyl methacrylate (HPMA-Cl)-based reactive monomer. The preparation procedure included pretreatment of the capillary inner wall, silanization, insitu graft polymerization with HPMA-Cl and PEI modification. To compare with the tentacle-type capillary column with PEI functionalization, a monolayer capillary column without PEI functionalization was also prepared. The electrochromatographic characterization of the prepared open tubular column was performed using alkylbenzenes. The electroosmotic flow (EOF) with regard to PEI concentrations and the running buffer pH was investigated. The separation conditions of the nucleosides and the proteins were optimized. The modified tentacle-type column with high anion exchange capacity has proven to afford better retention and resolution for the separation of nucleosides and proteins. The PEI functionalization column can also provide long-term stable use for biomolecule separation using a single capillary with relative standard deviation values of retention times of less than 2%. The results indicate that the present method for open tubular capillary preparation with a HPMA-Cl-based reactive monomer is promising for OT-CEC biomolecule separation. © 2014 the Partner Organisations.
URI
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84903555254&doi=10.1039%2fc3an01897k&partnerID=40&md5=1c54b6c179daa3209e0a524632ff2637
http://acikerisim.bingol.edu.tr/handle/20.500.12898/4834
Collections
  • Scopus İndeksli Yayınlar Koleksiyonu [1357]





Creative Commons License
DSpace@BİNGÖL by Bingöl University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 



| Politika | Rehber | İletişim |

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV