The Effects of HVDC Connection Line on Small Signal Stability in Four-Area Power System

Thumbnail
Tarih
2019
Yazar
Yildirim, B. and Yildiz, S. and Ozdemir, M.T.
Üst veri
Tüm öğe kaydını göster
Özet
High Voltage Direct Current (HVDC) systems which is a power electronics technology, will affect the control and stability of power systems with developments in power electronics. In this study, the effect of HVDC lines connected in parallel to High Voltage Alternating Current (HVAC) transmission lines on system stability and frequency oscillations were investigated in a four-area interconnected power system. The model of a four-area power system was created in Matlab / Simulink environment in this study. Two scenarios have been created for the study, the scenario of adding a HVDC connection between area 1 and area 2 and including the scenario of adding HVDC connection between area 1 and area 2 and between area 1 and area 3. Three different cases which are namely, only with alternating current (AC) connection, direct current (DC) connection parallel to AC lines and DC-connected state with phase-locked loop (PLL) parallel to AC lines were examined in each scenario cases. In a 4-area power system, the gains of the controllers were determined using the Optics inspired optimization (OIO) algorithm with Integral Squared Error (ISE) objective function. In the continuation of the study, eigenvalue analysis study was performed for 4-area power system whose controller gains were determined and eigenvalues of the models were obtained. Afterwards, relationship between eigenvalues and state variables was determined via sensitivity analysis. With the help of the analysis studies, it was tried to show the effects on the frequency oscillations and stability of the areas to which they are connected by adding HVDC connection lines with and without PLL to the power system. © 2019 IEEE.
Bağlantı
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85076338967&doi=10.1109%2fICPEA1.2019.8911165&partnerID=40&md5=dc62f97106e94b9363484cb9bad406ac
http://acikerisim.bingol.edu.tr/handle/20.500.12898/4079
Koleksiyonlar
  • Scopus İndeksli Yayınlar Koleksiyonu [1357]





Creative Commons License
DSpace@BİNGÖL by Bingöl University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 



| Politika | Rehber | İletişim |

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreBy TypeBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreBy Type

Hesabım

GirişKayıt

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV