Show simple item record

dc.contributor.authorTurhan, M.F. and Turşucu, A. and Akman, F. and Akdemir, F. and Durak, R.
dc.date.accessioned2021-04-08T12:06:09Z
dc.date.available2021-04-08T12:06:09Z
dc.date.issued2020
dc.identifier10.1016/j.radphyschem.2019.108564
dc.identifier.issn0969806X
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85074897718&doi=10.1016%2fj.radphyschem.2019.108564&partnerID=40&md5=451e26d032139c19aafadc0bca33165b
dc.identifier.urihttp://acikerisim.bingol.edu.tr/handle/20.500.12898/3856
dc.description.abstractKα, Kβ and total K X-ray fluorescence cross-sections, K shell fluorescence yields, Kβ/Kα X-ray intensity ratios, K to L shell vacancy transfer probabilities and Auger electrons emission ratios of some selected Mn and Ni compounds have been investigated. The measurements were carried out by using Am-241 radioactive source and high-resolution Si(Li) detector. The measured results were compared with other experimental values and theoretical calculations. Our values are in good concordance with calculated theoretical and other experimental values. © 2019 Elsevier Ltd
dc.language.isoEnglish
dc.sourceRadiation Physics and Chemistry
dc.titleChemical effect on K shell X-ray fluorescence parameters for some Mn and Ni compounds


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record