Show simple item record

dc.contributor.author
dc.contributor.author
dc.contributor.authorHan, İbrahim
dc.contributor.authorAkman, Ferdi
dc.date.accessioned2014-09-24T11:40:20Z
dc.date.available2014-09-24T11:40:20Z
dc.date.issued2012-01-01
dc.identifier.isbn978-81-7895-546-9
dc.identifier.urihttp://hdl.handle.net/11472/268
dc.description.abstractMass attenuation coefficients of the some elements were determined for two photon energies using different three detectors. The samples were irradiated using 10 mCi Cd-109 and 100 mCi Am-241 radioactive point sources. The photons were separately counted by Si(Li), NaI(Tl) and Cd(Tl) detectors. It was observed that the mass attenuation coefficient decreases with increasing energy and increases with increasing atomic number. The measured values are compared with the theoretical ones calculated using WinXcom program.tr_TR
dc.language.isoengtr_TR
dc.publisherTransworld Research Networktr_TR
dc.titleMeasurement of mass attenuation coefficients by Si(Li), NaI(Tl) and Cd(Tl) detectorstr_TR
dc.typeBook chaptertr_TR


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record