Calculation of surface leakage currents on high voltage insulators by ant colony algorithm-supported FEM

Thumbnail
Tarih
2015
Yazar
Ozturk, Dursun and Cebeci, Mehmet
Üst veri
Tüm öğe kaydını göster
Özet
The weakness of the outer insulation at high voltages is the reduction of the surface resistance as a result of the environmental pollution yielding formation of flashover due to the surface leakage currents. In this study, it was shown how to calculate the surface leakage currents resulting in flashover in polluted insulators and therefore power cuts by means of the ant colony algorithm (ACA). For this purpose, first, field distribution on the sample insulator surface in question was defined by the Laplace equation ( del(2) V = 0). With the help of the finite element method (FEM), the Laplace equation was obtained as an equation with a complex coefficient as a complex dielectric coefficient was used in the problem, which was converted to a set of linear equations. The solution of this problem was performed by FEM. For this purpose, a 2D finite element mesh was constructed for the area in question and the voltages at the nodes of this mesh were calculated. The current value was then calculated by transferring these voltages to the open model (AR model) obtained from the 3D model of the insulator. The ACA was used in the current calculations. After certain values of the leakage current, dry bands formed on the surface where partial arcs occurred as a result of the increase in voltage drops. Accordingly, rapid variations occurred in the current values and the electric field strengths. These variations, appearing until the formation of an arc throughout the whole leakage current distance, were calculated gradually by the ACA. The results obtained were presented graphically.
Bağlantı
http://acikerisim.bingol.edu.tr/handle/20.500.12898/2584
Koleksiyonlar
  • WOS İndeksli Yayınlar Koleksiyonu [374]





Creative Commons License
DSpace@BİNGÖL by Bingöl University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 



| Politika | Rehber | İletişim |

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreBy TypeBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreBy Type

Hesabım

GirişKayıt

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV